00100 \\M1BDR25;\M2NGR40;\M3NGR25;\M4NGR20;\F2\CSTANFORD UNIVERSITY
00200 \F3\CSTANFORD, CALIFORNIA 94305
00300 \F4COMPUTER SCIENCE DEPARTMENT\←L\-R\/'7;\+R\→.\→S Telephone:
00400 \←S\→.415-321-2300
00500 \F1\COctober 28,1973
00600
00700
00800
00900
01000 Dear Russ:
01100
01200 \J Enclosed youIll find some details of my idesa on
01300 just what sort of electronics package is necessary for the small arm.
01400 I intend to use a low cost unregulated power supply of +30 and -30 vdc. This will merely be a transformer,diode bridge and two
01500 filter capacitors. Regulated + and - 15 volts for the ic op-amps
01600 will come from an ic dual regulator module in the controller- this runs off
01700 of the dc supply voltage . The amplifiers initiall will be RCA HC2000H power
01800 operational amplifiers. These have a 7 amp. capability and a
01900 maximum supply voltage rating of 37 vdc. The motors use a maximum of 2 amperes at 30 vdc so these amplifiers are more than sufficient.
02000 To insure that the current limited motors never see a current greater than
02100 their max. allowable current, the amplifier is operated in a constant current configuration.
02200 This means that the output current to the motors is linearly proportional to
02300 the voltage in. This is just what you want for good arm control, as current is
02400 analogous to joint torque, and it appears that the controlled torque mode is the most desirable
02500 mode to operate in. The RCA amplifiers have been chosen over a less expensive,
02600 741 driven power amplifier, because they do not latch up when one half of the
02700 power supply dissappears. This is an important point, because the current limit
02800 in the motors is due to the demagnetization flux level of the magnet
02900 fields. Exceeding the max. current level in the armature for even 1 ms. is
03000 sufficient to demagnetize the motor and reduce its maximum torque output
03100 to a level much lower than the as delivered levels.
03200 \.\←L\→S\←R\-L\/'2;\+L\→L
03300
03400 Yours sincerely,
03500
03600
03700
03800 Victor Scheinman
03900